DRS Technologies Masthead

882-01

2000W/2500VA (Dual Input UPS)
882-01A

An uninterruptible power supply that continuously provides conditioned output power for demanding ground mobile applications.

pdfDownload Product Sheet
FEATURES
  • Dual AC or DC input power
  • Fully operable, and LRUs replaceable with MOPP Level IV gear in a Nuclear, Biological, Chemical contaminated environment
  • Fully operational following a Near Strike Lightening environment (MIL-STD-464 Para 5.4)
  • Designed to withstand and operate in harsh terrestrial environments
  • Universal AC Input power
  • Hot swap internal battery tray providing 10 min of backup power
  • Various Communications options available
  • Form Fit replacement for current V2 compliant UPS System

Input
AC Input Voltage80-265 VAC, single phase
Frequency45-66 Hz
DC Input Voltage (Optional)22-32 VDC, MIL-STD-1275B
AC Efficiency>80% at rated resistive load
DC Efficiency>80% at rated resistive load
Output
AC Output Voltage115 VAC, single phase, 60 Hz
AC Power Rating2000W (2500VA @ 0.8 pf)
Environmental
Operating Temperature-18°C to +52°C / 0°F to +125°F
Without Battery-28C to +50C / -18F to +122F
Storage Temperature-32ºC to +66ºC / -25ºF to +150ºF
EMI/EMCMIL-STD-461E; CE102, CS101, CS114. CS115, CS116, RE102 & RS103
VibrationOperate on the move in wheeled or tracked vehicles using the appropriate installation kit
ShockAir Drop, Transit Drop
HEMPMIL-STD-2169B
Batteries
BatteriesValve regulated sealed lead acid
Backup Time10 Minutes
Battery Charge Time85% in four hours
Physical
Dimensions
(LXWXH Inches)18.33 x 22.75 x 7.0
(LXWXH mm)466 x 578 x 177
Power Unit Weight (Including Batteries Max)

135 lbs / 61.2 kg

Tomorrow's Technology. Today.
>
© 2007 Property of DRS Pivotal Power, All rights reserved. User Agreement and Disclaimers